Project: TC4 | |
Date: 6/19/2009 9:37:00 AM | Pipe Segment Reference: TC4-M5-16 to TC4-M5-17 |
Street: Vincent St | Upstream MH: TC4-M5-16 |
Length Surveyed: 304.2 | Downstream MH: TC4-M5-17 |
Run Number: | Direction of Survey: Downstream |
Height (Diameter): 8 | Material: Vitrified Clay Pipe |
Distance |
Fault Observation |
Time |
Picture |
|
---|---|---|---|---|
0.0 |
Access Point Manhole
Severity: None Remarks: TC4-M5-16 |
00:00:00 00:00:00 |
||
0.0 |
Miscellaneous Water Level
Severity: None Percent: 10 |
00:00:00 00:00:00 |
||
7.0 |
Fracture Circumferential
Position: 6 To 1 Severity: None Percent: 0 Joint Struct Weight: 2 |
00:24:50 |
Distance |
Fault Observation |
Time |
Picture |
|
---|---|---|---|---|
7.5 |
Miscellaneous Water Level
Severity: None Percent: 10 |
00:00:44 |
||
11.4 |
Fracture Multiple
Position: 12 To 1 Severity: None Cont Defect: S01 Percent: 0 Joint Remarks: N/L Struct Weight: 4 |
00:01:56 |
||
21.1 |
Broken Soil Visible
Position: 9 To 1 Severity: None Percent: 0 Joint Struct Weight: 5 |
00:03:46 |
Distance |
Fault Observation |
Time |
Picture |
|
---|---|---|---|---|
21.1 |
Fracture Multiple
Position: 12 To 1 Severity: None Cont Defect: F01 Percent: 0 Joint Remarks: N/L Struct Weight: 4 |
00:04:02 |
||
36.0 |
Fracture Circumferential
Position: 12 To 1 Severity: None Percent: 0 Joint Remarks: N/L Struct Weight: 2 |
00:06:48 |
||
41.7 |
Broken Soil Visible
Position: 12 To 1 Severity: None Percent: 0 Struct Weight: 5 |
00:11:50 |
Distance |
Fault Observation |
Time |
Picture |
|
---|---|---|---|---|
45.9 |
Fracture Multiple
Position: 12 To 1 Severity: None Percent: 0 Joint Struct Weight: 4 |
00:12:57 |
||
91.8 |
Fracture Circumferential
Position: 2 To 1 Severity: None Percent: 0 Joint Struct Weight: 2 |
00:29:55 |
||
191.3 |
Roots Fine Lateral
Position: 9 Severity: None Maint Weight: 1 |
00:35:06 |
Distance |
Fault Observation |
Time |
Picture |
|
---|---|---|---|---|
191.3 |
Tap Break-in Activity
Position: 8 Severity: None Size: 6 |
00:34:47 |
||
192.8 |
Fracture Multiple
Position: 7 To 1 Severity: None Percent: 0 Joint Struct Weight: 4 |
00:36:33 |
||
203.0 |
Fracture Circumferential
Position: 11 To 2 Severity: None Percent: 0 Joint Struct Weight: 2 |
00:38:08 |
Distance |
Fault Observation |
Time |
Picture |
|
---|---|---|---|---|
218.0 |
Crack Longitudinal
Position: 12 Severity: None Percent: 0 Joint Struct Weight: 2 |
00:39:29 |
||
244.8 |
Crack Multiple
Position: 12 To 1 Severity: None Cont Defect: S02 Percent: 0 Joint Struct Weight: 3 |
00:41:25 |
||
258.7 |
Broken Soil Visible
Position: 12 To 1 Severity: None Percent: 0 Joint Struct Weight: 5 |
00:44:03 |
Distance |
Fault Observation |
Time |
Picture |
|
---|---|---|---|---|
258.7 |
Crack Multiple
Position: 12 To 1 Severity: None Cont Defect: F02 Percent: 0 Joint Struct Weight: 3 |
00:43:34 |
||
263.8 |
Broken Soil Visible
Position: 12 To 1 Severity: None Cont Defect: S03 Percent: 0 Joint Struct Weight: 5 |
00:45:23 |
||
267.2 |
Broken Soil Visible
Position: 12 To 1 Severity: None Cont Defect: F03 Percent: 0 Joint Struct Weight: 5 |
00:46:08 |
Distance |
Fault Observation |
Time |
Picture |
|
---|---|---|---|---|
273.5 |
Broken Soil Visible
Position: 12 To 1 Severity: None Joint Struct Weight: 5 |
00:47:38 |
||
283.7 |
Broken Soil Visible
Position: 12 To 1 Severity: None Cont Defect: S05 Percent: 0 Joint Struct Weight: 5 |
00:49:57 |
||
295.2 |
Broken Soil Visible
Position: 12 To 1 Severity: None Cont Defect: F05 Percent: 0 Joint Struct Weight: 5 |
00:50:45 |
Distance |
Fault Observation |
Time |
Picture |
|
---|---|---|---|---|
301.9 |
Crack Circumferential
Position: 12 To 1 Severity: None Percent: 0 Struct Weight: 1 |
00:52:53 |
||
304.2 |
Access Point Manhole
Severity: None Remarks: TC4-M5-17 |
00:53:32 |